This month I got called to a bedroom in Morganton where a receptacle had nearly started a fire. It was right under the homeowner's headboard. The outlet was an old 2-prong receptacle with a 2-to-3 prong adapter plugged into it. A surge protector with a long cord was plugged into the adapter, and a space heater was plugged into that. The adapter melted, the receptacle burned, and the wall above it was scorched black.


Most space heaters pull close to 1,500 watts, about 12 to 13 amps, for hours at a time. That's close to the limit of a standard 15-amp circuit. Every connection between the heater and your wiring has to carry that load: the plug, any adapter, any power strip, and the receptacle itself. If any of those connections is loose or worn, it heats up. Old receptacles lose their grip on plugs over the years, and that's when things start to melt.

I replaced the burned receptacle with a new GFCI receptacle, which adds shock protection on an older 2-wire circuit. If you have older wiring, ask me about arc-fault protection too. It's designed to catch damaged or loose connections that are arcing, which is how a lot of electrical fires start.